TY01-2000B
TENYU
| Availability: | |
|---|---|
| Quantity: | |
Engineered for immediate response and comprehensive property protection, this automatic fire extinguishing ball utilizes a non-toxic, eco-friendly ABC dry powder medium. It is specifically formulated to effectively suppress Class A (solid combustibles), Class B (flammable liquids), and Class C (electrical) fires. The internal powder is completely insulated and non-corrosive, ensuring that sensitive electronic equipment, server racks, and the surrounding environment remain safe from secondary chemical damage. Unlike traditional cylinders that require specialized personnel training and frequent maintenance, this device boasts an impressive 5-year maintenance-free lifespan. It requires no annual inspections or pressurized refilling, drastically reducing the total cost of ownership for large-scale facility management. Operating reliably in extreme industrial conditions ranging from -40°F to +200°F, it provides a 360-degree omnidirectional spray pattern, ensuring no blind spots during deployment, and can be seamlessly integrated with existing central fire alarm systems for synchronized smart building management.
1. Use environment: power distribution cabinets, commercial kitchens, heavy-duty warehouses, hospitality venues, shopping malls, maritime shipbuilding, and other fire-prone zones. The versatile, compact design allows it to adapt to diverse spatial constraints while providing immediate localized suppression, outperforming conventional extinguishers in tight or hard-to-reach areas.
2. Place the automatic fire extinguishing ball about 30 cm above potential fire hazards using the provided bracket or hook, following the direction of the arrow to face down. We highly recommend placing two units in the same location to achieve overlapping coverage zones and maximize suppression density.
3. Unmanned activation mechanism: If a fire occurs in an uninhabited environment, direct flame contact triggers the automatic reaction mechanism to disperse the extinguishing powder. This effectively smothers the fire source and prevents rapid spread. This 24/7 silent guardian acts independently, drastically lowering management overhead compared to manual firefighting equipment.
4. Manual deployment: When a fire is discovered, the unit can be safely thrown directly into the fire source without prior technical training. The extinguishing mechanism triggers within 3-5 seconds upon flame contact, accompanied by a piercing 120dB acoustic alarm. This sharp auditory alert immediately notifies nearby personnel, facilitating rapid evacuation and secondary emergency response.
5. Post-deployment cleanup: After the fire is totally extinguished, clean the site with a vacuum cleaner or standard sweeping tools. The fine, dry texture of the ABC powder allows for swift removal without leaving sticky residues, permanent stains, or corrosive moisture on commercial flooring and machinery.
To guarantee the reliable performance of your safety investment over its entire 5-year lifecycle, strict adherence to handling and environmental protocols is essential. We back this product with a comprehensive 5-year official quality guarantee, a 7-day return policy for unused units, and dedicated global technical support to ensure your procurement process is completely worry-free. The outer casing features a smooth, tactile finish engineered to be highly sensitive to direct flame contact, meaning improper handling could compromise its structural integrity. Please ensure all facility personnel are aware of the following operational boundaries.
1. The automatic fire extinguishing ball is designed to extinguish active fires only. It cannot be used for other purposes. Utilizing it as a testing device or training prop without actual fire presence will permanently deplete the unit.
2. The device should be stored or hung under normal temperature and dry environmental conditions when not deployed in specific extreme-temp zones. While it withstands severe conditions, prolonged exposure to excessive moisture or extreme freezing outside the rated parameters during storage may affect the flowability of the internal dry powder over extended periods.
3. Do not intentionally throw or ignite the automatic fire extinguishing ball for non-emergency purposes. Accidental drops on hard concrete floors from significant heights should be strictly avoided to prevent micro-fractures in the activation shell and ensure the fuse remains intact.
4. Intentional damage, dismantling, or altering the product is strictly prohibited. Breaking the factory seal or attempting to modify the internal fuse mechanism immediately voids the 5-year operational warranty, safety certifications, and our official after-sales support guarantees.
Produced in a highly regulated source factory, every automatic fire extinguishing ball undergoes rigorous visual and mechanical inspections. The manufacturing process relies on a strict ISO quality management system, ensuring that the ABC dry powder is precisely measured and securely sealed within the impact-resistant outer shell. From the initial molding of the spherical casing to the final integration of the heat-sensitive activation fuse, our production lines are optimized for consistency. The smooth exterior finish is engineered to resist dust accumulation in industrial settings, maintaining its bright, visible warning colors year after year.
We provide bespoke brand labeling, tailored exterior identification, and exclusive packaging solutions to meet specific regional compliance and branding requirements for diverse commercial projects.
Supported by standardized, large-scale production lines, we guarantee stable monthly capacity and rapid global delivery cycles to keep your engineering and construction projects on schedule.
Every bulk shipment utilizes shockproof and moisture-resistant international standard safety packaging. This ensures absolute protection during long-distance global logistics and complies with all regulations for the safe transport of specialized fire suppression equipment.
Meeting the strict demands of commercial and industrial building codes is a primary focus of our engineering team. This fire suppression unit has successfully passed comprehensive testing protocols to secure multiple international safety credentials, including CE and ISO certifications. These authoritative endorsements verify that the product performs reliably under extreme thermal stress and that the extinguishing medium is completely safe for human exposure during emergency evacuations. By integrating these certified units into your facility, you ensure full compliance with regional fire safety regulations, mitigating liability risks while providing tangible, proven protection for your workforce and physical assets. The reassuring weight and solid build quality of each unit reflect the rigorous testing standards applied during the certification process, offering peace of mind for large-scale procurement.
Deployment requires zero specialized plumbing, electrical wiring, or advanced technical training, significantly reducing installation labor costs. The intuitive mounting system is meticulously designed to provide a secure, vibration-resistant hold, yielding a satisfying, solid click when the unit is properly seated in its bracket. Below are the exact procedures to ensure optimal positioning over potential ignition sources.
* : The hanging product can be suspended directly in the target position. For open-ceiling architectures, heavy-duty suspension cables can be utilized to drop the unit exactly to the required operational height, ensuring the thermal activation fuse is perfectly aligned with rising heat currents.
1. Place the bracket at the intended installation location, then make precise markings for the bracket holes on the surface. With a drill, make holes on the markings the same size as the provided screw anchors. Ensure the wall material is structurally sound and can support the static weight of the unit without crumbling over time.
2. After the expansion bolt is securely inserted into the hole, place the bracket in the installation position. Pass the screw through the mounting hole of the bracket and screw it firmly into the expansion bolt. Tighten until the metal bracket sits completely flush against the wall surface, with no rattling or movement.
3. Place the automatic fire extinguishing ball securely on the bracket with the arrow pointing down. The clear directional arrow printed on the casing must face the floor to ensure the powder disperses in the correct downward conical pattern upon activation.
1. Place the mounting bracket in the target location on a stable flat surface, such as the top of a server rack, a heavy-duty storage shelf, or directly inside a large electrical distribution cabinet where Class C fire risks are present.
2. Place the automatic fire extinguishing ball securely on the bracket with the arrow pointing down. Verify that the unit is perfectly stable and will not roll, shift, or dislodge due to ambient machine vibrations or minor impacts.
HUIZHOU TENYU FIRE-FIGHTING TECH CO.,LTD. are comprehensive and specialized manufacturing enterprise integrating research and development, production and sales. TENYU TECH has always...